[53]: data by Dr.P.Gruber, Forch, Switzerland By continuing to browse the site you are agreeing to accept our use of cookies. [253]: data by Prof.Dr.M.Bhnke, Hamburg, Germany [50]: data by Dr.L.Henke, Gummersbach, Germany [320]: data by Dr.Mjn Carter, Bloemfontein, South Africa [333]: data by Dr. Alfredo Ferrer, Denia, Spain [314]: data by Dr.A.Vasavada et coll., Ahmedabad, India In two further optimisations, the formula . [16]: data by J.W.Klett, MD, Dortmund For Unique Device Identifier (UDI) information, select United States English and navigate to Help. [377]: data by Prof. Dr. Thomas Olsen, Aarhus, Denmark // -->, Clareon CNWTT0 PanOptix / CNWTTx PanOptix Toric, PanOptix TFNT00 Trifocal / TFNTxx Trifocal Toric, Tecnis 3-piece Multifocal ZMA00 +4.00 add, CT LUCIA 602 (previously Aaron Scientific EC-3 PAL). INDICATION: The ClareonAspheric Hydrophobic Acrylic IOLs include the Clareon Aspheric and Clareon Aspheric Toric IOLs and are indicated for primary implantation in the capsular bag in the posterior chamber of the eye for the visual correction of aphakia in adult patients in whom a cataractous lens has been removed. Oculentis L-402-1 discontinued A=118.0 a0= 1.58 a1=0.40 a2=0.10 pACD=5.75 sf=1.97 A=119.2 A=119.5 9 [106] [143]: data by Dr.K.Petermeier, Tbingen, Germany [208]: data by Dr.H.Domack, Schweinfurt, Germany Oculentis L-303 A=118.0 a0= 0.962 a1= -0.074 a2=0.161 pACD=5.13 sf=1.36 A=118.3 A=118.4 250 [119],[120],[117],[170],[120],[118],[160] [25]: data by Dr.U.Reinking, Salzkotten, Germany An Nd:YAG laser posterior capsulotomy was performed in 0.64% (13/2044) in the SA30AL group over a mean of 9 months (range 2 to 23 months) and in 0.34% (2/586) in the SA60AL group over a mean of 5.5 months (range 5 to 6 months). [364]: data by 1stQ, Mannheim, Germany [302]: data by Joseph R. Bishop III, Bluffton, SC, USA Europe / Middle East / Africa 033310/2 The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory A Swiss study comparing patient color perception and contrast sensitivity found that there was no difference in eyes implanted with a conventional UV-filtering IOL ( Clinical performance of alcon SA30AL and SA60AT single-piece acrylic intraocular lenses2. [236]: data by Dr.H.v.Wyk, Johannesburg, South Africa Please enable it to take advantage of the complete set of features! When did Woodrow Wilson marry his first wife? Based on 2 large datasets (1: N = 888 Hoya Vivinex aberration-correcting and 2: N = 822 Alcon SA60AT spherical lens) a classical formula constant optimisation has been performed for the Hoffer Q, Holladay 1, Haigis and Castrop formulae, to minimise the root mean squared (rms) PE (situation A). [266]: data by Dr. A. Hhn, Oldenburg, Germany [125]: data by P.Lockie MD, Geelong, Australia [133]: data by Keith Kellum, MD, Houma, LA, USA [287]: data by Dr. Alexander Tunas, Hamburg, Germany [338]: data by Dr. Ruth Lapid-Gortzak, Driebergen, The Netherlands The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. [110]: data by Dr.H.Wenkel, Coburg, Germany Optic glistenings were observed in 11 (11%) of 100 SA30AL cases at a mean follow-up of 8 months. [372]: data by Dr. W. Wehner, Nrnberg, Germany